ok
Direktori : /usr/lib/dracut/modules.d/95nbd/ |
Current File : //usr/lib/dracut/modules.d/95nbd/nbdroot.sh |
#!/bin/sh type getarg >/dev/null 2>&1 || . /lib/dracut-lib.sh PATH=/usr/sbin:/usr/bin:/sbin:/bin # Huh? Empty $1? [ -z "$1" ] && exit 1 # Huh? Empty $2? [ -z "$2" ] && exit 1 # Huh? Empty $3? [ -z "$3" ] && exit 1 # root is in the form root=nbd:srv:port[:fstype[:rootflags[:nbdopts]]] netif="$1" nroot="$2" NEWROOT="$3" # If it's not nbd we don't continue [ "${nroot%%:*}" = "nbd" ] || return nroot=${nroot#nbd:} nbdserver=${nroot%%:*}; nroot=${nroot#*:} nbdport=${nroot%%:*}; nroot=${nroot#*:} nbdfstype=${nroot%%:*}; nroot=${nroot#*:} nbdflags=${nroot%%:*} nbdopts=${nroot#*:} if [ "$nbdopts" = "$nbdflags" ]; then unset nbdopts fi if [ "$nbdflags" = "$nbdfstype" ]; then unset nbdflags fi if [ "$nbdfstype" = "$nbdport" ]; then unset nbdfstype fi if [ -z "$nbdfstype" ]; then nbdfstype=auto fi # look through the NBD options and pull out the ones that need to # go before the host etc. Append a ',' so we know we terminate the loop nbdopts=${nbdopts}, while [ -n "$nbdopts" ]; do f=${nbdopts%%,*} nbdopts=${nbdopts#*,} if [ -z "$f" ]; then break fi if [ -z "${f%bs=*}" -o -z "${f%timeout=*}" ]; then preopts="$preopts $f" continue fi opts="$opts $f" done # look through the flags and see if any are overridden by the command line nbdflags=${nbdflags}, while [ -n "$nbdflags" ]; do f=${nbdflags%%,*} nbdflags=${nbdflags#*,} if [ -z "$f" ]; then break fi if [ "$f" = "ro" -o "$f" = "rw" ]; then nbdrw=$f continue fi fsopts=${fsopts:+$fsopts,}$f done getarg ro && nbdrw=ro getarg rw && nbdrw=rw fsopts=${fsopts:+$fsopts,}${nbdrw} # XXX better way to wait for the device to be made? i=0 while [ ! -b /dev/nbd0 ]; do [ $i -ge 20 ] && exit 1 if [ $UDEVVERSION -ge 143 ]; then udevadm settle --exit-if-exists=/dev/nbd0 else sleep 0.1 fi i=$(($i + 1)) done # If we didn't get a root= on the command line, then we need to # add the udev rules for mounting the nbd0 device if [ "$root" = "block:/dev/root" -o "$root" = "dhcp" ]; then printf 'KERNEL=="nbd0", ENV{DEVTYPE}!="partition", ENV{ID_FS_TYPE}=="?*", SYMLINK+="root"\n' >> /etc/udev/rules.d/99-nbd-root.rules udevadm control --reload type write_fs_tab >/dev/null 2>&1 || . /lib/fs-lib.sh write_fs_tab /dev/root "$nbdfstype" "$fsopts" wait_for_dev -n /dev/root if [ -z "$DRACUT_SYSTEMD" ]; then printf '/bin/mount %s\n' \ "$NEWROOT" \ > $hookdir/mount/01-$$-nbd.sh fi fi if strstr "$(nbd-client --help 2>&1)" "systemd-mark"; then preopts="--systemd-mark $preopts" fi if [ "$nbdport" -gt 0 ] 2>/dev/null; then if [ -z "$DRACUT_SYSTEMD" ]; then nbd-client "$nbdserver" $nbdport /dev/nbd0 $preopts $opts || exit 1 else systemd-run --no-block --service-type=forking --quiet \ --description="nbd nbd0" \ -p 'DefaultDependencies=no' \ -p 'KillMode=none' \ --unit="nbd0" -- nbd-client "$nbdserver" $nbdport /dev/nbd0 $preopts $opts >/dev/null 2>&1 || exit 1 fi else if [ -z "$DRACUT_SYSTEMD" ]; then nbd-client -name "$nbdport" "$nbdserver" /dev/nbd0 $preopts $opts || exit 1 else systemd-run --no-block --service-type=forking --quiet \ --description="nbd nbd0" \ -p 'DefaultDependencies=no' \ -p 'KillMode=none' \ --unit="nbd0" -- nbd-client -name "$nbdport" "$nbdserver" /dev/nbd0 $preopts $opts >/dev/null 2>&1 || exit 1 fi fi # NBD doesn't emit uevents when it gets connected, so kick it echo change > /sys/block/nbd0/uevent udevadm settle need_shutdown exit 0